Airzing PRO - powered by OSRAM HNS UV lamps
Application guidelines
This linear fixture can be ceiling or wall mounted with an installation height measured from the floor between 2.5 and 4m. Cycle time to run fixture if the workspace is:
The coverage area of one set of fixture is 12-15m2
- <8m2, 30 mins is recommended
- 8 - 12m2, 45 mins is recommended
- 12 - 15m2, 60 mins is recommended
Product Name: AirZing PRO 5030
- Dimension:L 1058mm x W 54mm x H 78mm
- Input Voltage:220V±10%
- Input current:0.14A
- Power consumption:33W
- Lamp: OSRAM HNS 30W
- Operation temperature:-10°C~35°C
- Storage temperature:-20°C ~60°C
- Weight:1.3Kg(net) /1.9kg(package)
The coverage area of one set of fixture is 15-20m2
- <10m2, 30 mins is recommended
- 10 - 15m2, 45 mins is recommended
- 15 - 20m2, 60 mins is recommended
Product Name: AirZing PRO 5040
- Dimension:1363 mm x W 54mm x H 78mm
- Input Voltage:220V±10%
- Input current:0.19A
- Power consumption:40W
- Lamp: OSRAM HNS 36W
- Operation temperature:-10°C~35°C
- Storage temperature:-20°C ~60°C
- Weight:1.5Kg(net) /2.2kg(package)